Radar has been part of the level measurement market for more than thirty years. The early designs used in tank gauging were heavy, expensive, power-hungry and complex. Advancements in radar circuitry have evolved the modern radar transmitter so that now it is light, inexpensive, loop-powered and easy to use. The R82 is the logical extension of that evolution.

Microwave-based radar is a superior measurement technology with its ability to operate effectively in a wide range of process conditions. It has been too expensive to use as a replacement for ultrasonic transmitters in simple, daily applications…until now. The R82 radar transmitter can be considered the answer to almost every daily level measurement application imaginable.

Pulse burst radar

Technology

Pulse Burst Radar emits short bursts of energy to a liquid surface. Ultra-high-speed timing circuitry measures the time of the signal reflected off the liquid surface.

Sophisticated signal processing filters out false reflections and other background noises. The exact level is then calculated, by factoring in tank height and other configuration information. The circuitry is extremely energy efficient so no duty cycling is needed as with other radar devices. This allows the device to track high rates of level changes up to 4,5 m/minute (180″/min).

  • 24 VDC, loop-power with HART®
  • Housing: Lexan® or cast aluminum
  • Range: 15″ (380 mm) to 40 feet (12 m) measured from process connection
  • Antenna: Encapsulated horn – polypropylene or Tefzel®
  • Process Temperature: -40 to +200 °F (-40 to +93 °C)
  • Process Pressure: Vacuum to 200 psig (-1 to 13.8 bar)

Options

  • General Purpose and Intrinsically Safe approvals
  • Lexan or cast aluminum, single compartment housing
  • ¾” NPT or M20 conduit connections
  • Fully encapsulated antenna of polypropylene or Tefzel®
  • Process Connections: 2″ NPT or BSP
  • Antenna extensions for nozzle heights up to 12″ (300 mm)
Chemical
  • Lime slurry level
  • Neutralization
Common applications
  • Flow: Open channel flow
  • Level: Containment & drainage sumps
Crude oil
  • Drilling fluid tanks
  • Production Fluid Storage
Nuclear power
  • Emergency coolant tanks
Power generation
  • Water services
  • Water wash tanks
Pulp & paper
  • Mill water storage
  • Source water & bar screens
  • Turpentine Recovery
Renewable energy
  • Biofuel
  • Geothermal
Water & wastewater
  • Carbon slurry level
  • Clarifier level
  • Digester level
  • Filter tank level
  • Influent/effluent flow
  • Lift station pump control
  • Lime slurry level
  • Sludge level
  • Splitter box level
  • Water services
  • Water storage tanks
  • Water wash tanks

The R82 radar transmitter is based on pulse burst radar technology with equivalent time sampling circuitry. Short bursts of 26GHz microwave energy are emitted and subsequently reflected from the liquid level surface. Distance is calculated by the equation D = Transit time (round-trip)/2. Liquid level is then calculated by applying the user’s tank height and sensor offset values.

ATEX Ex ia
CCOE Ex ia
CSA IS, NI
EAC (GOST) Ex ia, Metrology
IEC Ex ia
Inmetro Ex ia
SIL SIL 1 (1oo1)

Other approvals are available.

+ Features
  • 24 VDC, loop-power with HART®
  • Housing: Lexan® or cast aluminum
  • Range: 15″ (380 mm) to 40 feet (12 m) measured from process connection
  • Antenna: Encapsulated horn – polypropylene or Tefzel®
  • Process Temperature: -40 to +200 °F (-40 to +93 °C)
  • Process Pressure: Vacuum to 200 psig (-1 to 13.8 bar)

Options

  • General Purpose and Intrinsically Safe approvals
  • Lexan or cast aluminum, single compartment housing
  • ¾” NPT or M20 conduit connections
  • Fully encapsulated antenna of polypropylene or Tefzel®
  • Process Connections: 2″ NPT or BSP
  • Antenna extensions for nozzle heights up to 12″ (300 mm)
+ Applications
Chemical
  • Lime slurry level
  • Neutralization
Common applications
  • Flow: Open channel flow
  • Level: Containment & drainage sumps
Crude oil
  • Drilling fluid tanks
  • Production Fluid Storage
Nuclear power
  • Emergency coolant tanks
Power generation
  • Water services
  • Water wash tanks
Pulp & paper
  • Mill water storage
  • Source water & bar screens
  • Turpentine Recovery
Renewable energy
  • Biofuel
  • Geothermal
Water & wastewater
  • Carbon slurry level
  • Clarifier level
  • Digester level
  • Filter tank level
  • Influent/effluent flow
  • Lift station pump control
  • Lime slurry level
  • Sludge level
  • Splitter box level
  • Water services
  • Water storage tanks
  • Water wash tanks
+ Operating principle

The R82 radar transmitter is based on pulse burst radar technology with equivalent time sampling circuitry. Short bursts of 26GHz microwave energy are emitted and subsequently reflected from the liquid level surface. Distance is calculated by the equation D = Transit time (round-trip)/2. Liquid level is then calculated by applying the user’s tank height and sensor offset values.

+ Approvals
ATEX Ex ia
CCOE Ex ia
CSA IS, NI
EAC (GOST) Ex ia, Metrology
IEC Ex ia
Inmetro Ex ia
SIL SIL 1 (1oo1)

Other approvals are available.

JOLAC ENGINEERING SDN BHD (“JOLAC”) was incorporated as private limited company in Kuala Lumpur, Malaysia under the Companies Act 1965 on 16th December 1982.